品牌 | 其他品牌 | 產品系列 | 其他 |
---|---|---|---|
額定電壓(V) | 三相AC480 | 適配電機功率 | 710kw |
濾波器 | 不帶濾波器 | 直流電源性質 | 電壓型 |
控制方式 | 其他 | 供電電壓 | 低壓 |
電源相數 | 三相 | 輸出電壓調節方式 | PAM控制 |
外型 | 其他 | 營銷方式 | 現貨 |
額定電流 | 380A |
西門子G120變頻器功率單元✘↟•☁◕,模組式變頻器✘↟•☁◕,3AC 380-480V✘↟•☁◕,USS/Modbus RTU 版本✘↟•☁◕,PROFINET 版本✘↟•☁◕,PROFIBUS DP 版本三個版本控制單元可供選擇組合✘↟•☁◕,滿足客戶的需求
SINAMICS G120C, frame sizes FSAA to FSF, with Intelligent Operator Panel IOP‑2
SINAMICS G120C compact converters offer a well-balanced combination of features to address a wide range of applications. They are compact, rugged devices that are easy to operate and can be optionally equipped with a basic or advanced operator panel.
SINAMICS G120C converters are especially suitable when it comes to meeting the requirements of system integrators, OEMs and distributors regarding high productivity and tailored performance.
G120C變頻器概述
Introduction
SINAMICS G120C compact converters
Line-side components
DC link components
Load-side power components
Supplementary system components
Spare parts
西門子G120變頻器功率單元
G120C緊湊型變頻器
SINAMICS G120C緊湊型變頻器✘↟•☁◕,在許多方面為同類變頻器的設計樹立了典範│•·。包括它緊湊的尺寸✘↟•☁◕,便捷的快速除錯✘↟•☁◕,簡單的面板操作✘↟•☁◕,方便友好的維護以及豐富的整合功能都將成為新的標準│•·。
SINAMICS G120C是專門為滿足OEM使用者對於高和節省空間的要求而設計的變頻器✘↟•☁◕,同時它還具有操作簡單和功能豐富的特點│•·。這個系列的變頻器與同類相比相同的功率具有更小的尺寸✘↟•☁◕,並且它安裝快速✘↟•☁◕,除錯簡便✘↟•☁◕,以及它友好的使用者接線方式和簡單的除錯工具都使它與眾不同│•·。整合眾多功能☁·↟│:安全功能(STO,可透過端子或PROFIsafe)✘↟•☁◕,多種可選的通用的現場匯流排介面✘↟•☁◕,以及用於引數複製的儲存卡槽│•·。
SINAMICS G120C 變頻器包含三個不同的尺寸功率範圍從0.55kW到18.5kW│•·。為了提高能效✘↟•☁◕,變頻器集成了向量控制實現能量的最佳化利用並自動降低了磁通│•·。該系列的變頻器是全整合自動化的組成部分✘↟•☁◕,並且可選PROFIBUS, Modbus RTU,CAN以及USS 等通訊介面│•·。操作控制和除錯可以快速簡單地採用PC機透過USB介面✘↟•☁◕,或者採用BOP-2(基本操作面板)或IOP(智慧操作面板)來實現│•·。[2]
5日常維護
操作人員必須熟悉西門子變頻器的基本工作原理↟·↟₪↟、功能特點✘↟•☁◕, 具有電工操作常識│•·。在對變頻器日常維護之前✘↟•☁◕,必須保證裝置總電源全部切斷;並且在變頻器顯示完全消失的3-30分鐘(根據變頻器的功率)後再進行│•·。應注意檢查電網電壓✘↟•☁◕,改善變頻器↟·↟₪↟、電機及線路的周邊環境✘↟•☁◕,定期清除變頻器內部灰塵✘↟•☁◕,透過加強裝置管理極大限度地降低變頻器的故障率│•·。
1↟·↟₪↟、冷卻風扇
變頻器的功率模組是發熱嚴重的器件✘↟•☁◕,其連續工作所產生的熱量必須要及時排出✘↟•☁◕,一般風扇的壽命大約為20kh~40kh│•·。按變頻器連續執行折算為3~5年就要更換一次風扇✘↟•☁◕,避免因散熱不良引發故障│•·。
2↟·↟₪↟、濾波電容
中間電路濾波電容☁·↟│:又稱電解電容✘↟•☁◕,該電容的作用☁·↟│:濾除整流後的電壓紋波✘↟•☁◕,還在整流與逆變器之間起去耦作用✘↟•☁◕,以消除相互干擾✘↟•☁◕,還為電動機提供必要的無功功率✘↟•☁◕,要承受極大的脈衝電流✘↟•☁◕,所以使用壽命短✘↟•☁◕,因其要在工作中儲能✘↟•☁◕,所以必須長期通電✘↟•☁◕,它連續工作產生的熱量加上變頻器本身產生的熱量都會加速其電解液的乾涸✘↟•☁◕,直接影響其容量的大小│•·。正常情況下電容的使用壽命為5年│•·。建議每年定期檢查電容容量一次✘↟•☁◕,一般其容量減少20%以上應更換│•·。
3↟·↟₪↟、防腐劑的使用
因一些公司的生產特性✘↟•☁◕,各電氣mcc室的腐蝕氣體濃度過大✘↟•☁◕,致使很多電氣裝置因腐蝕損壞(包括變頻器)│•·。
為了解決以上問題可安裝一套空調系統✘↟•☁◕,用正壓新鮮風來改善環境條件│•·。為減少腐蝕性氣體對電路板上元器件的腐蝕✘↟•☁◕,還可要求變頻器生產廠家對線路板進行防腐加工✘↟•☁◕,維修後也要噴塗防腐劑✘↟•☁◕,有效地降低了變頻器的故障率✘↟•☁◕,提高了使用效率│•·。
4↟·↟₪↟、給變頻器除塵☁·↟│:變頻器根據使用環境的不同✘↟•☁◕,應定期檢查散熱通道↟·↟₪↟、及電路板中有無積累灰塵✘↟•☁◕,一般每半年清理一次✘↟•☁◕,至少也要一年清理一次✘↟•☁◕,以確保變頻器散熱良好✘↟•☁◕,使其避免因散熱不良而引發故障│•·。
在保養的同時要仔細檢查變頻器✘↟•☁◕,定期送電✘↟•☁◕,帶電機工作在2hz 的低頻約10分鐘✘↟•☁◕,以確保變頻器工作正常│•·。
G120C 一體式變頻器
USS/Modbus RTU 版本
不帶濾波器訂貨號
6SL3210-1KE11-8UB2 0.55kW
6SL3210-1KE12-3UB2 0.75kW
6SL3210-1KE13-2UB2 1.1kW
6SL3210-1KE14-3UB2 1.5kW
6SL3210-1KE15-8UB2 2.2kW
6SL3210-1KE17-5UB1 3kW
6SL3210-1KE18-8UB1 4kW
6SL3210-1KE21-3UB1 5.5kW
6SL3210-1KE21-7UB1 7.5kW
6SL3210-1KE22-6UB1 11kW
6SL3210-1KE23-2UB1 15kW
6SL3210-1KE23-8UB1 18.5kW
6SL3210-1KE24-4UB1 22kW
6SL3210-1KE26-0UB1 30kW
6SL3210-1KE27-0UB1 37kW
6SL3210-1KE28-4UB1 45kW
6SL3210-1KE31-1UB1 55kW
6SL3210-1KE31-4UB1 75kW
6SL3210-1KE31-7UB1 90kW
6SL3210-1KE32-1UB1 110kW
6SL3210-1KE32-4UB1 132kW
帶濾波器訂貨號
6SL3210-1KE11-8AB2
6SL3210-1KE12-3AB2
6SL3210-1KE13-2AB2
6SL3210-1KE14-3AB2
6SL3210-1KE15-8AB2
6SL3210-1KE17-5AB1
6SL3210-1KE18-8AB1
6SL3210-1KE21-3AB1
6SL3210-1KE21-7AB1
6SL3210-1KE22-6AB1
6SL3210-1KE23-2AB1
6SL3210-1KE23-8AB1
6SL3210-1KE24-4AB1
6SL3210-1KE26-0AB1
6SL3210-1KE27-0AB1
6SL3210-1KE28-4AB1
6SL3210-1KE31-1AB1
6SL3210-1KE31-4AB1
6SL3210-1KE31-7AB1
6SL3210-1KE32-1AB1
6SL3210-1KE32-4AB1
PROFINET 版本
不帶濾波器訂貨號
6SL3210-1KE11-8UF2
6SL3210-1KE12-3UF2
6SL3210-1KE13-2UF2
6SL3210-1KE14-3UF2
6SL3210-1KE15-8UF2
6SL3210-1KE17-5UF1
6SL3210-1KE18-8UF1
6SL3210-1KE21-3UF1
6SL3210-1KE21-7UF1
6SL3210-1KE22-6UF1
6SL3210-1KE23-2UF1
6SL3210-1KE23-8UF1
6SL3210-1KE24-4UF1
6SL3210-1KE26-0UF1
6SL3210-1KE27-0UF1
6SL3210-1KE28-4UF1
6SL3210-1KE31-1UF1
6SL3210-1KE31-4UF1
6SL3210-1KE31-7UF1
6SL3210-1KE32-1UF1
6SL3210-1KE32-4UF1
帶濾波器訂貨號
6SL3210-1KE11-8AF2
6SL3210-1KE12-3AF2
6SL3210-1KE13-2AF2
6SL3210-1KE14-3AF2
6SL3210-1KE15-8AF2
6SL3210-1KE17-5AF1
6SL3210-1KE18-8AF1
6SL3210-1KE21-3AF1
6SL3210-1KE21-7AF1
6SL3210-1KE22-6AF1
6SL3210-1KE23-2AF1
6SL3210-1KE23-8AF1
6SL3210-1KE24-4AF1
6SL3210-1KE26-0AF1
6SL3210-1KE27-0AF1
6SL3210-1KE28-4AF1
6SL3210-1KE31-1AF1
6SL3210-1KE31-4AF1
6SL3210-1KE31-7AF1
6SL3210-1KE32-1AF1
6SL3210-1KE32-4AF1
PROFIBUS DP 版本
不帶濾波器訂貨號
6SL3210-1KE11-8UP2
6SL3210-1KE12-3UP2
6SL3210-1KE13-2UP2
6SL3210-1KE14-3UP2
6SL3210-1KE15-8UP2
6SL3210-1KE17-5UP1
6SL3210-1KE18-8UP1
6SL3210-1KE21-3UP1
6SL3210-1KE21-7UP1
6SL3210-1KE22-6UP1
6SL3210-1KE23-2UP1
6SL3210-1KE23-8UP1
帶濾波器訂貨號
6SL3210-1KE11-8AP2
6SL3210-1KE12-3AP2
6SL3210-1KE13-2AP2
6SL3210-1KE14-3AP2
6SL3210-1KE15-8AP2
6SL3210-1KE17-5AP1
6SL3210-1KE18-8AP1
6SL3210-1KE21-3AP1
6SL3210-1KE21-7AP1
6SL3210-1KE22-6AP1
6SL3210-1KE23-2AP1
6SL3210-1KE23-8AP1
G120C變頻器引數設定步驟
一↟·↟₪↟、引數設定步驟
1.使用網線連線上G120C變頻器,開啟博圖找到相應的變頻器轉至線上模式│•·。
線上模式
2.進入“引數設定"
選擇引數
3.進入引數模式後將預設模式改成擴充套件引數│•·。
模式選擇
4.在下方框內直接輸入引數編號可直接查到並對其進行修改│•·。
編號輸入
5.點選左側選單選擇“儲存/復位"選項✘↟•☁◕,進入儲存復位畫面│•·。在如下的畫面紅色框中點選“儲存"按鈕✘↟•☁◕,講設定的引數儲存至變頻器的EEPROM中✘↟•☁◕,如果設定的引數沒有儲存至EEPROM中變頻器在斷電後設置的引數會丟失✘↟•☁◕,完成儲存設定後把變頻器轉至離線模式✘↟•☁◕,變頻器設定完畢│•·。
儲存
二↟·↟₪↟、主要引數
1↟·↟₪↟、加減速時間✘↟•☁◕,最小減速時間✘↟•☁◕,VDC直流母線控制模式✘↟•☁◕,複合制動係數✘↟•☁◕,VDC直流母線嚮應係數✘↟•☁◕,控制模式✘↟•☁◕,極限電流✘↟•☁◕,直流制動啟用│•·。
主要引數
三↟·↟₪↟、報警遮蔽設定
1.P2118是遮蔽的報警編號✘↟•☁◕,P2119是無報警資訊設定✘↟•☁◕,兩者是一一對應使用│•·。
- 上一篇☁·↟│:西門子變頻器維修
- 下一篇☁·↟│:西門子G120XA風機水泵專用變頻器